Materials Laboratory Failure Analysis
Failure can be defined as any change in a component that prevents satisfactory performance of

Failure can be defined as any change in a component that prevents satisfactory performance of

CREEP FATIGUE IN STEAM COOLED BOILER AND HRSG TUBES By: Wendy Weiss Creep-fatigue is caused


Strain-Induced Precipitation Hardening, also known as SIPH, is a commonly misinterpreted boiler tube failure mechanism

CIRCUMFERENTIAL THERMAL FATIGUE IN CONVENTIONAL WATERWALL TUBES By: Wendy Weiss Circumferential Thermal Fatigue damage in

PITTING CORROSION IN CONVENTIONAL FOSSIL BOILERS AND COMBINED CYCLE/HRSGS By: Wendy Weiss Pitting is a

MATERIALS LABORATORY CASE STUDY 6 THE PROBLEM A supplier of electromagnetic interference (EMI) components noticed

MATERIALS LABORATORY CASE STUDY 5 THE PROBLEM A filter was removed from a stator cooling

MATERIALS LABORATORY CASE STUDY 4 THE PROBLEM Structural Integrity received a section of an original

MATERIALS LABORATORY CASE STUDY 3 THE PROBLEM Structural Integrity received several sections of core reinforcing