News & Views, Volume 48 | Implementation of Material Verification – In Support of Mega-Rule Part 1 Requirements

By:  Roger Royer, Scott Riccardella, and David BabbittNews & View, Volume 48 | Implementation of Material Verification In Support of Mega-Rule Part 1 Requirements

Operators are now required to define sampling programs and perform destructive (laboratory) or non-destructive testing to capture this information and take additional actions when inconsistent results are identified until a confidence level of 95% is achieved.

Various sections of Mega-Rule 1 require operators of natural gas transmission pipelines to ensure adequate Traceable, Verifiable, and Complete (TV&C) material records or implement a Material Verification (MV) Program to confirm specific pipeline attributes including diameter, wall thickness, seam type, and grade. Operators are now required to define sampling programs and perform destructive (laboratory) or non-destructive testing to capture this information and take additional actions when inconsistent results are identified until a confidence level of 95% is achieved.  Opportunistic sampling per population is required until completion of testing of one excavation per mile (rounded up to the nearest whole number) up to 150 excavations (if the population exceeds 150 miles).  Regulators have communicated an expectation that sampling locations or test sites are to be equally spaced throughout the population mileage.